What we help with
-
MV Transformers are the last step down so that customers can use the voltage. Typically, these MV Transformers are 5kV up to 35kV, but some applications will be higher in voltage. This equipment is going to fall under the IEEE standard C57.12.00, NEMA, ANSI C57, and DOE.
300-7000kva
Up to 35kV input
-
Electrical switchgear refers to a centralized collection of circuit breakers, fuses and switches (circuit protection devices) that function to protect, control and isolate electrical equipment. The circuit protection devices are mounted in metal structures. A collection of one or more of these structures is called a switchgear line-up or assembly.. Rugged construction provides superior strength and durability, and all switchgear is designed to meet seismic and wind load requirements.
OFCI Mission Critical offers a broad variety of metal-clad switchgear designs including:
Voltages: 5kV to 38kV
Metal-enclosed interrupter switchgear
Dual rated switchgear
Automatic transfer switchgear
Gas, Air, Shield Solid insulated technologies
-
OFCIMS offers a comprehensive line of busduct, busduct parts, and components for a safe and reliable system. We have both Segregated and Non-segregated bus from 600V up to 38kV with ratings up to 10000 amps along with NEMA 3R for outdoor applications. On our LV busway is designed up to 6000amp and allows for maximum flexibility.
-
Low-voltage switchgear provides short-circuit and overload protection via low-voltage power circuit breakers (LV-PCB) with integral trip units. These low-voltage circuit breakers are typically through-the-door, or draw-out devices. These boards are typically UL 891 or UL 1558
Up to 600V
Up to 12000amp buss
Up to 200kVA short circuit withstand rating
Integrated Automatic Transfer switch
-
A UPS is an uninterruptible power supply. These devices fall under the UL1778 listing. UPS systems are typically paired with a DC source to allow a ride through when the power fails. These DC sources can be Lithium ION, VRLA, Nickle Zinc, etc type batteries. In the event the customer does not desire a battery system these UPS can be paired flywheel. OFCIMS offers a board range of UPS systems:
120V up to 15KV
1kVA up to 2MVA
Parallel and standalone systems
Battery and Battery less systems
-
Power distribution Units or PDUS fall under UL 60950 listing. Floor mounted PDUs accomplish three primary tasks within a mission critical facility.
They provide a stepdown voltage for facilities, typically between the UPS and critical load.
They can provide a neutral source along with providing impedance to lessen fault current.
They provide distribution for the electrical system.
PDUs come and many different configurations. Here at OFCIMS we can provide a wide range of PDU and also offer completely customized PDUs
Up to 600V rated
Up to 2MVA
Raised floor or slab mounted
Top or bottom input and output
Branch Circuit Monitoring
IR windows
Bus temp monitoring for zero IR Scanning required
Separated controls section
-
OFCIMS offers a complete line of RPPS that allows full customization to meet your customer needs. 2 panel, 3 panel, 4 panel RPPs touch safe, easy access to controls, branch circuit monitoring, and much more.
Up to 600V
Up to 4 panels in one frame
BCMS
Isolated ground
Finger safe design
Separated controls section
-
Open channel busway is busway that allows the customer to install bus plugs along the entire length of the busway with no restrictions on place do to openings. This type of busway is typically found within the data center whitespace, lab areas, or spaces that customers need the ability to quickly provide add and changes. OFCIMS offers a large range of busway options:
Up to 600V rated
Up to 1200amp
Configurations that can support up to 200amp bus plugs
Load bank connections
Branch Circuit Monitoring and busway and bus plugs
Multiple mounting types Item description
-
Item description
-
Item description